11/0.4kV Sab nraum zoov Switchgear 500kva Transformer Substation
Sab nraum zoov transformer substation muaj xws li (1) Nruab nrab / High voltage compartment, (2) Low voltage compartment (3) transformer compartment.HV & LV compartment yog ua tiav muaj nuj nqi. HVcompartment muaj ntau txoj hauv kev siv hluav taws xob thaum kuaj cov khoom siv hluav taws xob hauv 1 lub sijhawm, nws kuj tuaj yeem nruab nrog HVtesting cov cuab yeej kom ncav cuag qhov kev thov ntawm HVtesting. Lub transformer compartment yuav xaiv tau S7, S9 los yog lwm yam tsawg noj roj immersed transformer thiab qhuav hom transformer. Lub transformer compartment muaj tsis siv neeg pib cua txias tshuab thiab teeb pom kev zoo systems.Low voltage compartment yuav ua tau raws li cov neeg siv 'xav tau, nws adopts ruaj los yog assembled qauv los ua hluav taws xob fais fab system, nws muaj ntau yam zoo li lub teeb tis, fais fab faib, reactive. Lub zog, hluav taws xob ntsuas hluav taws xob .. thiab lwm yam txhawm rau txhim kho lub zog xa khoom zoo thiab txaus siab rau cov neeg siv khoom.Qhov no substation lub cev feem ntau muaj cov khoom siv hlau, cov khoom siv hlau tsis muaj steel, cov khoom tsis yog hlau ... uas tuaj yeem xaiv los ntawm cov neeg siv khoom thiab cov neeg siv khoom. Nws yog ib qho tseem ceeb ntawm cov khoom siv hluav taws xob thiab cov khoom siv hluav taws xob hauv hluav taws xob cable fais fab net.it yog ib hom kev ua tiav ntawm cov khoom siv hluav taws xob nrog HVcontrolling, kev tiv thaiv thiab kev hloov pauv, kev faib tawm.. siv nyob rau hauv industrial thiab mining enterprises, nyob rau hauv lub quarters, tsev kho mob, khw, high-sawv vaj tse thiab lwm yam tis systems.Rau no substation, peb mas tsim & export 11KV, 15KV, 20KV, 24KV, 33KV hom.
Hauj lwm lawm
11/0.4kV sab nraum zoov switchgear 500kva transformer substation
Khoom nta:
1.Nws tuaj yeem txuag tau av zoo heev, tsis tas yuav av thiab kev tsim kho pej xeem, thiab txuag kev nqis peev hauv vaj tse.
2.Nws tsis muaj teeb meem hauv av, tsis cuam tshuam rau ib puag ncig, thiab tsis cuam tshuam rau tib neeg lub zeem muag thiab thaj chaw.
3.Cov hom faus tag nrho ntsia rau ntawm cov nyom thiab txoj siv ntsuab kuj tuaj yeem tsim nrog qee cov khoom siv zoo nkauj rau hauv av, xws li sculptures, rockery, thiab lwm yam; Yog tias hauv av yuav tsum tsis muaj kev cuam tshuam (nrog rau cov qhov cua nkag), koj tuaj yeem xaiv square hom prefabricated substation.
4.Cov khoom siv hluav taws xob faib hluav taws xob ntawm cov khoom siv faus rau hauv prefabricated substation yog teem rau hauv av, uas muaj kev nyab xeeb thiab txhim khu kev qha.
5.Qhov av tsis cuam tshuam los ntawm lub suab nrov transformer.
6.Raws li hauv av yog qhov ntxoov ntxoo thiab txias, qhov kub thiab txias ntawm lub transformer yog qhov ruaj khov thaum lub sijhawm ua haujlwm.
7.Qhov chaw sab hauv ntawm lub faus prefabricated substation yog qhov dav, thiab kev saib xyuas yuav tsis ua rau muaj kev cuam tshuam rau hauv av, thiab yuav tsis cuam tshuam rau ib puag ncig ib puag ncig.
1 Ambient kub: -25 degree ~ ntxiv rau 40 degree
2 Qhov siab: tsawg dua 1000m
3 txheeb ze humidity
Qhov nruab nrab nruab nrab txhua hnub tsawg dua 95 feem pua Qhov nruab nrab tus nqi ntawm cov dej vapor siab tsawg dua 2.2kpa
Lub hli nruab nrab tsawg dua 90 feem pua Qhov nruab nrab tus nqi ntawm cov dej vapor siab tsawg dua 1.8kpa
4 Seismic siv: tsawg dua qhov magnitude 8
5 Sab nraum cua ceev tsawg dua 35m / s
6 Siv rau qhov chaw tsis muaj hluav taws kub, tsis muaj kev phom sij tawg thiab tsis muaj tshuaj lom neeg corrosion
Technical data
| Tsis muaj. | ||
| 1. | General | |
| Chaw tsim tshuaj paus | FENGYUAN Factory | |
| Hom | FENGYUAN | |
| ntau lawm / kuaj tus qauv | IEC 62271-1, IEC 62271-200, IEC 62271-202, IEC 62271-202, IEC 60076, IEC 61439, IEC 60529, IEC 62262, IEC 60721 | |
| Kev sib xyaw ntawm kev faib khoom substation | ||
| No. ntawm nruab nrab voltage (15KV) compartment | 1 | |
| Tsis muaj qhov hluav taws xob tsawg (0.4kv) chav tsev | 1 | |
| No. of distribution transformer 1250KVA 15/0.4KV | 1 | |
| 2 | 15 KV nruab nrab voltage compartment | |
| chav kawm tiv thaiv | IP43 | |
| Service ntsuas voltage | 15 KV | |
| Voltage variation ntawm qhov system | 10 feem pua | |
| permissible max.operating voltage | 17.5 kV | |
| Tso cai mx khoom ntsuas voltage | 24 KV | |
| 2.1 | RMU- Nplhaib Lub Ntsiab Tseem Ceeb (incoming 2 plus outgoing 1) | |
| 2.1.1 | LBS (Load break switch) nrog lub ntiaj teb hloov | 2 |
| hom | lub tshuab nqus tsev | |
| Ntau zaus | 50/60 Hz | |
| Fais fab zaus withstand voltage, KV (RMS) | 38 | |
| Rated xob laim impulse withstand voltage. KV (Peak) | 95 | |
| Rated tam sim no (Amp) | 630 | |
| Rated luv-lub sij hawm tiv taus tam sim no rau 1S (KA) | 25 | |
| 2.1.2 | Nqus Circuit Court breaker (VCB) nrog lub ntiaj teb hloov & cais x 1 | |
| HOM | Lub tshuab nqus tsev | |
| Rated zaus | 50/60 Hz | |
| Fais fab zaus withstand voltage, KV (RMS) | 38 | |
| Rated xob laim impulse withstand voltage. KV (Peak) | 95 | |
| ntsuas tam sim no (A) | Deponds ntawm qhov ntsuas ntawm lub transformer | |
| ntsuas luv-lub sij hawm tiv taus tam sim no rau 1s (KA) | 25 | |
| 3 | Tsawg voltage compartment | |
| chav kawm tiv thaiv | IP23 | |
| 3.1 | Main cua Circuit Court breaker | 2500A / 50 KA, 400V, 3 Ncej |
| 3.2 | CT - tam sim no transformer | |
| QTY rau txhua qhov S / S | 3 | |
| Kev ntsuas hluav taws xob | 380V | |
| CT Ratio | 2500/5 A | |
| Ntau zaus | 50/60 Hz | |
| lub nra | 15 VAJ | |
| Chav kawm | 1.0 | |
| 3.3 | Ampmeter | 3 pcs, 0-2500 A |
| 3.4 | Voltmeter nrog selector hloov | 1 pc, 0-500 V |
| 4 | Transformer compartment | |
| windings khoom ntawm transformer | koom tes | |
| chav kawm tiv thaiv | IP23 | |
| txheem | IEC60076 | |
| Txoj kev txias | ONAN | |
| HOM | 3 Theem roj rau hom (los yog hom qhuav) | |
| rated nruam fais fab ntawm HV sab & LV sab | 1250 KVA AW | |
| Rated thawj voltage | 15 KV | |
| Rated theem nrab voltage | 0.4 KV | |
| Vector pawg | Dyn5 (los yog Dyn11) | |
| Tsis-load poob ntawm qhov ntsuas voltage thiab zaus (KW) | Tsawg dua lossis sib npaug rau 0.95 | |
| Tag nrho cov load poob (KW) | Tsawg dua los yog sib npaug 11 | |






PRODUCTION LINE

CERTIFICATE




EXHIBITION

LUB TSEV KAWM NTAWV

FAQ
Q5 : Puas yog OEM / ODM muaj?
A: Yog, nws yog! Peb cov khoom tuaj yeem tsim kho. Peb muaj pab pawg tsim thiab engineers, peb tuaj yeem kho cov khoom raws li cov neeg siv khoom kos duab lossis cov kev xav tau.
Q6 : Koj yog cov chaw tsim khoom lossis tuam txhab lag luam?
A: Peb yog lub Hoobkas, Raws li 100 feem pua ntawm cov chaw tsim khoom nrog 20 xyoo kev tsim khoom, peb tuaj yeem tsim cov khoom raws li cov neeg siv khoom xav tau thiab peb tuaj yeem tswj cov khoom zoo 100 feem pua.
Q7 : Tus nqi puas tuaj yeem sib tham?
A: Yog, tus nqi yog sib tham. Nws tuaj yeem hloov pauv raws li koj qhov ntau lossis pob
Q8 :Yuav ua li cas rau kev soj ntsuam?
A: Peb muaj tag nrho cov kev tshuaj xyuas los ntawm cov khoom siv raw mus rau qhov kawg cov khoom suav nrog kev ntsuas kub nce, ntsev tsuag tshuaj ntsuam xyuas tus neeg xyuas pib hom kev xeem, kev sim lub neej.
Q9 :Cov nqe lus them nqi yog dab tsi?
A: T.T, Paypal, Western Union, Alibaba kev ruaj ntseg kev lag luamthiab L/C yog txais tau. 30% T / T ua ntej,70 feem puatshuav nyiaj li cas ua ntej khoom xa tuaj.
NYEEM VIDEO
https://www.facebook.com/bob.niu.35/
Youtube
www.youtube.com/channel/UC5IP4dL0UTQG4fgAOa3UhWA
https://twitter.com/FengyuanE
Txais tos kom nug
Cov ntaub ntawv tiv tauj:
Jiyuan Fengyuan Electrical Equipment Co., Ltd
Kev Muag Khoom
Hu rau tus neeg: Mr Charles Du
E-mail:fengyuan800@outlook.com
Txawb: ntxiv rau 8618639199897(Muaj rau whatsapp, wechat, skype)
Ntxiv: Huling industrial tsam, jiyuancity, henan xeev, Suav teb
TEL: ntxiv rau 86-0391-2180800
Fax: plus 86-0391-2180818
Cim npe nrov: 11/0.4kv sab nraum zoov switchgear 500kva transformer substation, Tuam Tshoj, manufacturers, lwm tus neeg, customized