YB Tos Miskas Hloov Chaw Hloov Chaw
Pre-installed Transformer Substation lus piav qhia AC hlau kaw hom hloov hloov txee yog peb-theem AC 50HZ sab hauv cov cuab yeej siv hlau ua hluav taws xob, siv nyob rau hauv cov chaw ua hluav taws xob thiab chaw hloov hluav taws xob nrog qhov ntsuas hluav taws xob ntawm 35kV, qhov ntsuas siab tshaj tam sim no ntawm 2000A, thiab a ib qho chaw tos tsheb loj lossis ntu ...
Hauj lwm lawm
YB tos ntsia Asmeskas hloov chaw:
Cov khoom no tso rau lub siab siv hluav taws xob hloov pauv thiab cov hluav taws xob loj fuse hauv cov roj transformer, thiab muaj ob daim qauv txheej txheem: tib lub thawv lossis lub thawv xa nrog lub cev hloov pauv; cov roj tank txais kev tsim kev kaw ruaj ruaj, thiab nruab nrog cov roj ntsuas kub, ntsuas qhov ntsuas roj, ntsuas qhov ntsuas, Siab nyem valve, roj ntws valve thiab lwm yam khoom los saib xyuas cov haujlwm ntawm hloov pauv; raws li cov khoom siv hluav taws xob tseem ceeb hauv cov xaib faib khoom siv hauv lub network, cov khoom no yog ua tiav cov khoom siv ua ntej tsim cov khoom siv nrog cov ntsuas hluav taws xob, tiv thaiv, hloov kho thiab hloov khoom siv fais fab. Siv nyob hauv nroog thiab hauv nroog loj faib chaw.
1. Qhov siab: ≤1000m; ambient kub; -25 ℃ ~ +40 ℃;
2. Kev ntsuas kub: qhov siab tshaj plaws txhua hli nruab nrab +30 ℃, qhov nruab nrab txhua xyoo kub tshaj plaws +20 ℃;
3. Cov ntsuas cua zoo: qhov nruab nrab txhua hnub tus nqi tsis yog ntau dua 95%, tus nqi nruab nrab txhua hli tsis ntau tshaj 90%;
4. Kev tiv thaiv kom tsis txhob muaj siab: qib nrawm 0 4m / s, ntsug nrawm nrawm O 15m / s;
5. Lub chaw teeb tsa tsis yog lub zog; tsis muaj kev cuam tshuam loj heev, tsis muaj kuab lom thiab tshuaj xeb, tsis muaj plua plav paug lossis tawg ua paug.
Box-type substations siv nyob rau hauv cov tsev siab siab, vaj tsev kim heev, thaj chaw ua si, thaj chaw thaj chaw, cov chaw ua haujlwm me thiab nruab nrab, cov chaw me, thaj chaw roj thiab cov tsev nyob ib ntus kom tau txais thiab faib hluav taws xob hauv lub tshuab hluav taws xob.



Lub ntsiab kev tsis raug | |||
HV chav tsev | Nyob ua ntau zaus | Hz | 50 |
Rated voltage | kV | 7.2 12 24 40.5 | |
Rated tam sim no ntawm cov tsheb loj | A | 630 1250 1600 | |
Nyob luv-lub sij hawm withstand tam sim no / ntev | kA / s | 20/4 25/3 31.5/4 | |
Nyob ncov toj tam sim no | kA | 50 63 80 | |
1min fais fab zaus tso hluav taws xob (rau-hauv pem teb / ntawm qhib kev sib cuag) | kV | 32/36 42/48 65/79 95/115 | |
Xob laim impulse withstand voltage (rau-hauv av / ntawm qhib kev sib cuag) | kV | 60/70 75/85 125/145 185/215 | |
Rho luv-Circuit Court tawg tam sim no | kA | 20 25 31.5 | |
Lub voj voos ncua luv-lub sij hawm nrog tam sim no / sijhawm | kA / s | 20/2 20/4 | |
Rho luv-Circuit Court ua tam sim no ntawm lub voj loj | kA | 50 63 80 | |
Nyob ua ke load thauj tam sim no | A | 630 | |
Rated kaw lub voj ua txhaum tam sim no | A | 630 | |
Nyob hloov tam sim no | A | 1700 | |
Mechanical lub neej peroid | sij hawm | 3000 5000 10000 | |
Chav tsev LV | Nyob ua ntau zaus | Hz | 50 |
Rated voltage | kV | 0.4/0.23 | |
Rated rwb thaiv tsev voltage | V | 690 | |
Rated tam sim no ntawm lub voj tseem ceeb | A | 100~3200 | |
Nyob luv-lub sij hawm nrog tam sim no | kA / s | 30/1 50/1 100/1 | |
Nyob ncov toj tam sim no | kA | 63 105 176 | |
5s fais fab zaus tiv taus voltage | kV | 2.5 3.75 | |
Chav tsev Transformer | Nyob ua ntau zaus | Hz | 50 |
Rated voltage | kV | 7.2 12 24 40.5/0.4 | |
Cov movies muaj peev xwm | kVA | 30~1600 | |
1min fais fab zaus tiv taus voltage | kV | 25/20 35/28 55/50 85/75 | |
Xob laim impulse tiv taus voltage | kV | 60 75 125 170 | |
Impedance voltage | % | 4~6 | |
Tapping ntau | ... | ±×2.5% ±×5% | |
Pawg sib txuas | ... | Y , yn0 D, yn11 | |
Hom | ... | Roj-raus hom, hom qhuav | |
Lub cev txee | Tus IP code ntawm HV thiab LV lag | ... | IP33D |
Tus IP code ntawm transformer chamber | ... | IP23D | |
Suab theem (roj-raus hom / qhuav hom) | dB | ≤50/55 | |

Thov hu rau peb yog tias koj xav tau
Cim npe nrov: yb pre-install american substation, Tuam Tshoj, tuam ntxhab, cov chaw muag khoom, kho kom haum