33 KV 40.5 KV High Voltage Switchgear
1 Txheej txheem cej luam KYN61-40.5 high voltage switchgear yog haum rau peb-theem AC 50Hz/40.5kV ib lub tsheb npav thiab ib lub tsheb npav ib ntu fais fab. Nws yog dav siv nyob rau hauv cov chaw nres tsheb fais fab, substations, industrial thiab mining lag luam kom tau txais thiab faib hluav taws xob hluav taws xob. Lub tsev siab. Nws tuaj yeem ...
Hauj lwm lawm
1 Txheej txheem cej luam
KYN61-40.5 high voltage switchgear yog tsim rau peb -theem AC 50Hz / 40.5kV ib lub tsheb npav thiab ib lub tsheb npav ib ntu hluav taws xob. Nws yog dav siv nyob rau hauv cov chaw nres tsheb fais fab, substations, industrial thiab mining lag luam kom tau txais thiab faib hluav taws xob hluav taws xob. Lub tsev siab. Nws tuaj yeem tswj, tiv thaiv thiab saib xyuas circuits.,
Qauv | KYN61-40.5 |
Rated voltage | 40.5 |
Ntau zaus | 50 HZ |
Rated Tam sim no | 1250A/1600A/2000A |
IP Qib | IP3X |
Ib puag ncig kub | -10 C~+40 C |
Cov khoom siv | specification |
Kev Qhia Txog Kev Kho Mob | Yuav tsum tau ntxuav thiab muab tso rau hauv qhov chaw qhuav |
KYN61-40.5 switchgear yog peb theem AC 50 Hz, ntsuas qhov hluav taws xob ntawm 40.5 KV cov khoom siv hluav taws xob sab hauv tsev.Raws li cov chaw tsim hluav taws xob, cov chaw siv hluav taws xob thiab kev lag luam kev puas tsuaj ntawm hluav taws xob nkaus xwb, thiab muaj kev siv hluav taws xob hauv hluav taws xob, kev tiv thaiv thiab saib xyuas kev ua haujlwm.
KYN61-40.5 tshem tau AC hlau-clad switchgear siv rau 40.5kV, 3 theem, AC thiab 50/60Hz hluav taws xob hluav taws xob network rau kev txais thiab xa tawm lub zog hluav taws xob thiab tseem rau kev tswj, saib xyuas thiab tiv thaiv ion. Nws muaj feem xyuam rau lub zog dav dav thiab lub sijhawm nrog kev ua haujlwm nquag. Cov khoom ua raws li GB3906: 3 ~ 35kV AC Hlau Enclosed Switchgear, IEC60694 & GB/T11022: Cov lus qhia dav dav ntawm HV Switchgear thiab controlgear Standard, DL/T404-1997: Order Technical term of Indoor AC HV Switchgear 14kV AC {g{G} thiab tswj tus qauv.
Ib puag ncig tej yam kev mob
1) Qhov kub thiab txias: -10℃~ +40 degree, Qhov kub nruab nrab txhua hnub: Tsawg dua lossis sib npaug li 35℃.
2) Haum Qhov siab: Tsawg dua lossis sib npaug li 1000m
3) Tus txheeb ze Humidity: Txhua hnub txhais tau tsawg dua lossis sib npaug li 95%, txhua hli txhais tau tsawg dua lossis sib npaug li 90%
4) Kev puas tsuaj ntawm av qeeg: Tsawg dua lossis sib npaug rau Qib 8
Cov sij hawm siv tau yuav tsum tsis muaj corrosives, inflammables thiab vapors.
2. Nta
-Ntau yam kev hloov pauv tuaj yeem ua tau nrog lub siab -voltage compartment qhov rooj kaw.
-Lub txee hloov pauv yog hlau clad thiab kaw. Kev tiv thaiv qib ntawm lub plhaub yog IP4X kom ntseeg tau tias muaj kev nyab xeeb ntawm tus kheej.
-Nws muaj kev tiv thaiv hluav taws xob zoo.
-Cov qauv me me thiab cov hneev taw me me.
-Nws muaj qhov yooj yim los siv ntau yam haujlwm thiab ua tau raws li qhov xav tau sib txawv.
-Txoj kev rho tawm tuaj yeem hloov pauv tau. Tsiv lub trolley ntawm lub vaj huam sib luag yog kev ua haujlwm - txuag thiab ruaj khov.
-Nws muaj qhov chaw txaus hauv chav cable rau txuas ntau lub cables. Yooj yim rau nruab thiab tswj.
- Yooj yim thiab txhim khu kev qha mechanical interlock
Structure Description:
Switchgear raws li G83906 thiab IEC298 tus qauv thiab tsim, Thiab tuaj yeem raug tshem tawm ntawm lub txee raws li tag nrho chav tsev (trolley) cov khoom.
Txee qauv yog ua los ntawm txhuas deposited zine phaj los yog galvanized daim ntawv sib dhos nrog ob qho tib si kev twb kev txuas, cais Circuit Court breaker switchgear roon, tsheb npav, chav tsev cable thiab ntsuas chav tsev, Tag nrho cov hlau Cheebtsam yog grounded, txhua compartment ntawm lub ntsiab Circuit Court .system muaj cais tso tawm channel nyob rau hauv lub cable compartment yuav teem 10 .
Cov yam ntxwv tseem ceeb:
1.Kev siv cov khoom sib dhos ua ke, cov khoom siv hluav taws xob hluav taws xob hauv tsev,
Loj loj:
2.Optional: Lub tuam txhab lub tshuab nqus tsev vacuum VW1-40.5, xiamen huadian lub tshuab nqus tsev vacumm breaker VEP-40.5, zoo sib xws Circuit Court breaker yog interchangeable.
3.Txhim kho cov tsheb thauj khoom tshwj xeeb tuaj yeem nqa, tsheb thauj mus los amd txee kom raug qhov chaw, xauv thiab txhim khu kev qha
4.Lub ntsiab hloov, lub tawb nqa khoom, lub qhov rooj sib cuam tshuam ntawm qhov yuav tsum tau siv lub tshuab ntsuas phoo yog siv los ua kom tau raws li 'Tsib Anti' interlock muaj nuj nqi.
5.Txhua txoj haujlwm tuaj yeem ua tiav ntawm lub qhov rooj kaw lub xeev, los tiv thaiv kev nyab xeeb ntawm tus neeg teb xov tooj.
6.Cable qhov chaw txaus, tuaj yeem txuas nrog ntau lub cables, thiab cov khoom siv hluav taws xob.
7.Shell tiv thaiv qib IP3X, handcart chav qhov rooj qhib nruab nrab ntawm ntau yam kev tiv thaiv chav kawm IP2X.
8.Cov ntaub ntawv tuaj yeem ua cov ntawv galvanized tuaj yeem tso rau alumimum zinc phaj ntau lawm.
3. Specifications
Tsis muaj. | Cov khoom | Chav tsev | Parameters | ||
1 | Rated voltage | KV | 40.5 | ||
2 | Rated zaus | Hz | 50 | ||
3 | Lub ntsiab busbar ntsuas tam sim no | A | 1250,1600,1200 | ||
4 | Ceg busbar ntsuas tam sim no | A | 630/1250/ 1600 | ||
5 | Rated rwb thaiv tsev theem | Fais fab zaus withstand voltage nyob rau hauv 1min (zoo tus nqi) | Phase-phase, Phase- hauv av | KV | 95 |
Kev sib cais thawj zaug | KV | 115 | |||
Lightning Impulse Withstand Voltage (tus nqi siab tshaj) | Phase-phase, Phase- hauv av | KV | 185 | ||
Kev sib cais thawj zaug | KV | 215 | |||
Fais fab zaus withstand voltage ntawm pab tswj Circuit Court | V | 2000 | |||
6 | Rated luv Circuit Court breaking tam sim no | KA | 25/31.5 | ||
7 | Rated luv Circuit Court kaw tam sim no (peak tus nqi) | KA | 63/80 | ||
8 | Rated luv -lub sij hawm tiv taus tam sim no (4S) | KA | 25/31.5 | ||
9 | Rated ncov tiv tau tam sim no | KA | 63/80 | ||
10 | Rated voltage ntawm pab tswj Circuit Court | V | -110,-220,~220 | ||
11 | Qib tiv thaiv | Enclosure IP4X, IP2X Thaum lub qhov rooj ntawm Circuit Court breaker qhib | |||
12 | Qhov loj me (dav * qhov tob * qhov siab) | mm | 1400 (1200) * 2800 (2600) * 2600 (* suav nrog cov txheej txheem SF6 sab hauv) | ||
13 | hnyav | kg | ~2300 | ||
PRODUCT PHOTO







CHAW UA HAUJ LWM

PACKING & xa khoom


EXHIBITION

FAQ
Q5: Puas yog OEM / ODM muaj?
A: Yog, nws yog! Peb cov khoom tuaj yeem tsim kho. Peb muaj pab pawg tsim thiab engineers, peb tuaj yeem kho cov khoom raws li cov neeg siv khoom kos duab lossis cov kev xav tau.
Q6: Koj puas yog cov chaw tsim khoom lossis tuam txhab lag luam?
A: Peb yog Hoobkas, Raws li 100% cov chaw tsim khoom nrog 20 xyoo kev tsim khoom, peb tuaj yeem tsim cov khoom raws li cov neeg siv khoom xav tau thiab peb tuaj yeem tswj cov khoom zoo 100%.
Q7: Tus nqi puas tuaj yeem sib tham?
A: Yog, tus nqi sib tham. Nws tuaj yeem hloov pauv raws li koj qhov ntau lossis pob
Q8: Ua li cas txog kev tshuaj xyuas?
A: Peb muaj tag nrho cov kev tshuaj xyuas los ntawm cov khoom siv raw mus rau qhov kawg cov khoom suav nrog kev ntsuas kub nce, ntsev tsuag tshuaj ntsuam xyuas tus neeg xyuas pib hom kev xeem, kev ntsuas lub neej.
Q9: Cov nqe lus them nqi yog dab tsi?
A: TT, Paypal, Western Union, Alibaba kev lees paub kev lag luam thiab L / C tau txais . 30% T / T ua ntej, 70% tshuav nyiaj ua ntej xa khoom.
Q10: Lub tuam txhab muab kev pabcuam yog dab tsi?
A: Peb muaj cov kws tshaj lij engineer pab pawg uas tuaj yeem tsim thiab tsim pwm kom tuaj txog cov neeg siv khoom sib txawv.
Peb kuj muaj pab pawg muag khoom los muab kev pabcuam zoo los ntawm kev ua ntej- muag rau tom qab- muag.
Cov lus qhia rau kev tsocai thiab muab Order:
Tus neeg siv khoom yuav tsum qhia cov khoom hauv qab no:
♠ Daim phiaj xwm phiaj xwm phiaj xwm thiab ib qho - kab kab kab ke
♠ Secondary circuit schematic daim duab, yog tias tus neeg siv khoom tsis muaj qhov yuav tsum tau ua, nws yuav tsum tau xaim raws li lub Hoobkas qauv;
♠ Cov txheej txheem ntawm lub tshuab hloov pauv, cov phiaj xwm hauv pem teb ntawm lub chaw nres tsheb.
♠ Cov lus qhia ntxaws thiab tsis muaj cov khoom siv hluav taws xob ntawm txhua lub voj voog;
♠ Cov xim saum npoo ntawm cov khoom siv hloov;
♠ Lwm yam yuav tsum tau ua.
Cov khoom no feem ntau yog customized.
Peb yog cov chaw tsim khoom thiab muaj lub tuam txhab kev tshaj lij uas tuaj yeem tsim thiab muab kev daws teeb meem raws li cov neeg siv khoom xav tau.
Thov hu rau peb cov neeg muag khoom kom tau txais cov duab kos duab
Nov yog peb cov neeg siv khoom piv txwv rau koj siv
Uzbekistan cov neeg siv khoom
Cov ntaub ntawv
1.1 710-512-01-MVS1 Main Substation
Nkag mus Switchgear A01 B01 2
Tsis muaj Cheebtsam Specification Unit Qty Maker
1 VCB
HVX12-50-31-F 275mm
Qhov siab tsawg dua lossis sib npaug li 2000m
Qhib voltage DC 220V
Kaw voltage DC 220V
Lub zog cia voltage DC220V
Teeb 1 Suav
2 VT JDZ-10 10KV/√3/0.1KV/√3 Set 3 China
3 CT ib
LZZBJ9-12 3000/1A 5P20 10VA
5P20 5VA 5Fs5 5VA
Teeb 3 Suav
4 High voltage fuse XRNP1-12 0.5A Pc 3 Tuam Tshoj
5 Hluav taws xob ntes HY5WZ-17/50 Teeb 3 Tuam Tshoj
6 Intelligent tswj vaj huam sib luag WY-9008A Pc 1 Tuam Tshoj
7 Qhov taw qhia luv luv Circuit Court thiab av txhaum EKL-4-1 Pc 1 Tuam Tshoj
8 Multifunctional hluav taws xob ntsuas PD666-3S 3 380V 5A Pc 1 Tuam Tshoj
9 Thawj Harmonic tshem tawm LXQ-12KV PC 1 Fengyuan
10 Charged zaub DXN-12Q Pc 1 Tuam Tshoj
11 Kub thiab av noo tswj WY-CS-III Pc 1 Tuam Tshoj
12 Txuas daim JY-2 Pc 3 Tuam Tshoj
13 Junction box PJ1 Pc 1 Tuam Tshoj
14 Metering bracket Universal hom Pc 1 Tuam Tshoj
15 teeb liab teeb liab ND16-22D / 4 AC380V liab Pc 1 CHNT
16 teeb liab teeb liab ND16-22D / 4 AC380V ntsuab Pc 1 CHNT
17 Lub teeb liab teeb liab ND16-22D / 4 AC380V dawb Pc 1 CHNT
18 AC me me Circuit Court breaker NB1-63 / 2P C6A 6kA (R) Pc 2 Fengyuan
19 AC me me Circuit Court breaker NB1-63 / 3P C3A 6kA (R) Pc 1 Fengyuan
20 DC me me Circuit Court breaker NB1Z-63 2P C6 Pc 1 Fengyuan
21 AC me me Circuit Court breaker NB1-63 / 3P B2A 6kA (R) Pc 1 Suav teb
22 Universal xeem davhlau ya nyob twg RURTK/S Pc 30 Tuam Tshoj
23 Universal Terminal Block RUK 5B Pc 18 Tuam Tshoj
24 Txawb sab saum toj me me tsheb npav Ø 6 tooj liab bar m 11 Fengyuan
Yog xav paub ntxiv, thov koj xav tias dawb hu rau peb
Cim npe nrov: 33 kv 40.5 kv high voltage switchgear, Suav teb, manufacturers, lwm tus neeg, customized