40.5kv
video
40.5kv

40.5kv Hlau Armored Switchgear

KYN61-40.5 hlau hloov pauv hlau tau tsim los raws li cov cuab yeej tiv thaiv cov hlau txuas nrog hauv GB3906-2006. Nws yog qhov tsim nyog rau peb-theem AC ntsuas hluav taws xob 40.5kV, ntsuas zaus 50Hz zog zog. Nws yog siv rau txais thiab faib hluav taws xob hluav taws xob thiab tswj hwm, tiv thaiv thiab ...

Hauj lwm lawm

KYN61-40.5 hlau hloov pauv hlau tau tsim los raws li cov cuab yeej tiv thaiv cov hlau txuas nrog hauv GB3906-2006. Nws yog qhov tsim nyog rau peb-theem AC ntsuas hluav taws xob 40.5kV, ntsuas zaus 50Hz zog zog. Nws yog siv rau kev txais thiab faib cov khoom siv hluav taws xob thiab tswj hwm, tiv thaiv thiab tshawb xyuas cov khoom siv hluav taws xob.


40.5kv Metal Armored Switchgear


Kev qhia tshwj xeeb

Nyob voltage (KV): 40.5

Fais fab zaus tiv qhov hluav taws xob (KV): 95 (1min)

Impulse withstand voltage (KV): 185

Rated zaus: 50Hz

Nyob tam sim no (A): 1250/1600/2000

Rated thermal stability tam sim no (KA 4S): 25/31.5/40

Rated dynamic ruaj khov tam sim no (KA): 63/80

Rated luv-Circuit tawg tam sim no (KA): 25/31.5/40

Rated luv-Circuit ua tam sim no (KA): 63/80

Qhov ntsuas hluav taws xob (V) ntawm kev qhib thiab kaw thiab cov khoom sib txuas DC: 24, 36, 48, 60, 110, 220, AC: 110, 220

Kev tiv thaiv qib: IP3X


Siv ib puag ncig ib puag ncig

(1) Ib puag ncig ib puag ncig ib puag ncig

1. Qhov txwv qis tshaj ntawm huab cua puag ncig: +40 ​​℃, qis dua: -10 ℃, thiab qhov nruab nrab nruab nrab txhua hnub kub tsis tshaj 35 ℃;

2. Qhov siab tsis tshaj 1000m;

3. Tus txheeb ze qhov kub thiab txias tsis tshaj 95% txhua hnub, thiab qhov nruab nrab txhua hli tsis tshaj 90%;

4. Kev siv av qeeg tsis tshaj 8;

5. Tus nqi nruab nrab txhua hnub ntawm cov pa dej siab tsis tshaj 2.2Kpa, thiab tus nqi nruab nrab txhua hli tsis tshaj 1.8kpa;

6. Tsis muaj hluav taws txaus ntshai, muaj kuab paug loj, tshuaj lom neeg xeb thiab qhov chaw hnyav nyob hauv lub tsev no.

(2) Cov haujlwm tshwj xeeb, thov tham nrog peb

Metal Armored Switchgear

Cov yam ntxwv tseem ceeb

1. Cov txheej txheem txee tau txais hom kev sib sau ua ke, thiab lub tshuab hluav taws xob hluav taws xob txais yuav lub tsheb laij teb hom qauv

2. Nruab nrog ib yam tshiab ntawm kev sib txuas hluav taws xob nqus lub tshuab nqus tsev, thiab muaj cov yam ntxwv ntawm kev sib pauv tau zoo thiab yooj yim;

3. Cov ntsia hlau ntsia hlau thawb lub tshuab tau teeb tsa hauv lub thav duab thav duab, uas tuaj yeem txav tau lub laub kom yooj yim thiab tiv thaiv kev ua haujlwm tsis raug los ntawm kev ua kom puas tus qauv.

4. Txhua txoj haujlwm tuaj yeem ua tiav nrog lub qhov rooj txee kaw;

5. Qhov cuam tshuam ntawm qhov hloov pauv tseem ceeb, lub laub nqa khoom thiab hloov lub qhov rooj txais yuav cov txheej txheem xauv uas yuav tsum tau ua

6. Muaj qhov chaw txaus nyob hauv chav cable thiab ntau txoj hlua txuas tuaj yeem txuas nrog;

7. Qhov hloov pauv hauv av nrawm yog siv rau hauv av thiab kaw luv-Circuit Court;

8. Qib kev tiv thaiv ntawm lub plhaub yog IP3X, thiab qib tiv thaiv yog IP2X thaum lub qhov rooj ntawm chav xauv lub qhov rooj qhib;

9. Cov khoom ua raws GB3906-2006, DL/T 04-2007 thiab lees txais thoob ntiaj teb IEC 928 tus qauv los ntawm kev siv.


40.5kv Switchgear

Cim npe nrov: 40.5kv hlau armored switchgear, Tuam Tshoj, tuam ntxhab, cov chaw muag khoom, kho kom haum

(0/10)