Hlau -clad AC Switchgear
KYN61-40.5 Hlau-clad AC Switchgear Cov khoom no yog ua tiav cov khoom siv hluav taws xob sab hauv tsev nrog peb-theem AC 50Hz thiab ntsuas qhov hluav taws xob ntawm 405kV. Nws tuaj yeem siv los ua cov chaw tsim hluav taws xob, cov chaw siv hluav taws xob thiab cov chaw lag luam thiab cov lag luam mining kom tau txais thiab faib hluav taws xob hluav taws xob. Nws muaj ...
Hauj lwm lawm
KYN61-40.5 Hlau-clad AC Switchgear
Cov khoom no yog ua tiav cov khoom siv hluav taws xob sab hauv tsev nrog peb -theem AC 50Hz thiab ntsuas qhov hluav taws xob ntawm 405kV. Nws tuaj yeem siv los ua cov chaw tsim hluav taws xob, cov chaw siv hluav taws xob thiab cov chaw lag luam thiab cov lag luam mining kom tau txais thiab faib hluav taws xob hluav taws xob. Nws muaj kev ua haujlwm xws li kev tswj hwm, kev tiv thaiv thiab kev tshawb nrhiav ntawm Circuit Court, thiab tseem tuaj yeem siv rau hauv qhov chaw uas nquag ua haujlwm.
Siv ib puag ncig
1. Ambient cua kub: -15 degree ntxiv rau 40 degree;
2. Qhov siab: 2000m thiab hauv qab;
3. Humidity tej yam kev mob:
Qhov nruab nrab cov av noo txhua hnub: Tsawg dua lossis sib npaug li 95 feem pua, txhua hnub nruab nrab cov dej vapor siab tsis tshaj 2.2kPa;
Lub hli nruab nrab cov av noo: Tsawg dua lossis sib npaug li 90 feem pua, qhov nruab nrab ntawm cov dej vapor siab tsis tshaj 1.8kPa txhua hnub.
4. Kev siv av qeeg: tsis ntau tshaj 8 degrees;
5. Cov chaw uas tsis pom muaj kuab paug xws li corrosive lossis flammable gases;
Nco tseg: Thaum cov kev siv ib txwm siv dhau lawm, tus neeg siv tuaj yeem sib tham nrog lub tuam txhab.

Main technical parameters ntawm switchgear
Yam khoom | Chav tsev | Cov ntaub ntawv |
Rated voltage | KV | 40.5 |
Rated tam sim no | A | 1250 1600 2000 |
Rated zaus | Hz | 50 |
Rated luv -lub sij hawm tiv taus tam sim no | kA | 20 25 31.5 |
Reted ncov tiv taus tam sim no | kA | 50 63 80 |
Rated fais fab - zaus tiv taus voltage | KA | 95 |
Rated teeb pom kev zoo impulse withstand voltage | kV/1 min | 185 |
Rated luv -lub sijhawm | kV ua | 4 |
Chav kawm tiv thaiv | S | IP3X |


Ordering plan:
1. Muab cov phiaj xwm kab hluav taws xob xov tooj, lub hom phiaj thiab ib qho - kab kab ke kab ke, ntsuas hluav taws xob, ntsuas tam sim no, thiab lwm yam.
2. Cov kev xav tau rau kev tswj, ntsuas thiab kev tiv thaiv kev ua haujlwm ntawm switchgear thiab lwm yam khoom siv xauv thiab tsis siv neeg.
3. Thaum lub switchgear yog siv nyob rau hauv tshwj xeeb tej yam kev mob, nws yuav tsum tau piav qhia nyob rau hauv kom meej thaum txiav txim.
4. Thaum xav tau lwm yam khoom siv lossis ntau dua thiab cov khoom seem, yuav tsum tau thov cov hom thiab ntau.
Hoobkas


Daim ntawv pov thawj

Packing Kev xa khoom

Tiv tauj peb:
Hu rau: Charles Du
Txawb: ntxiv rau 86 18639199897
E-mail:Fengyuan800@outlook.com
Qhov kev xaiv zoo tshaj plaws rau kev lag luam hluav taws xob!
Thov tso cov lus nug kom paub meej ntxiv txog cov nqi, ntim khoom, shipping thiab luv nqi.
Cim npe nrov: hlau -clad ac switchgear, Tuam Tshoj, manufacturers, lwm tus neeg, customized