GCS tsawg voltage rho tawm switchgear txee yog tsim rau peb-theem AC zaus ntawm 50Hz, rated ua hauj lwm voltage ntawm 380V, rated tam sim no ntawm 4000A thiab hauv qab no nyob rau hauv lub hwj chim tiam / fais fab mov system raws li lub hwj chim, faib thiab lub cev muaj zog centralized tswj, electrofusion nyiaj. Cov khoom ua raws li iec60439-1, gb7251.1, JB / t9661 thiab lwm yam qauv

Hauj lwm lawm

Cov khoom siv hluav taws xob GCK LV thim tau hloov pauv

Tsawg voltage switchgear, tseem hu ua low-voltage switchgear, feem ntau yog siv nyob rau hauv lub low-voltage tis ib feem ntawm lub hwj chim system thiab feem ntau ntsia nyob rau hauv lub chav faib. Nws muaj xws li lub davhlau ya nyob twg thaiv, ntau yam hloov pauv, cov cuab yeej tiv thaiv (cua hloov pauv, fuses, thiab lwm yam), ntsuas cov cuab yeej (voltmeter, ammeter, thiab lwm yam), thiab cov cuab yeej ntsuas ntsuas (cov khoom siv hluav taws xob thiab hluav taws xob reactive, thiab lwm yam).

Muab faib ua ob hom: hom tub rau khoom thiab hom ruaj khov; Cov hom ruaj khov yog hais txog kev teeb tsa ruaj khov, thaum hom tub rau khoom yog hais txog kev hloov pauv hloov pauv ntawm qee yam khoom siv hluav taws xob rau hauv ob peb lub chaw ua haujlwm raws li ib qho kev ua haujlwm hauv Circuit Court, thiab tom qab ntawd mus rau hauv vaj huam sib luag (txheej txheem). Txhua chav ua haujlwm zoo ib yam li lub tub rau khoom, tab sis nws tuaj yeem rub tawm lossis UI zoo li, yog li nws tseem hu ua hom rub tawm. Feem ntau ntsia tawm ntawm phab ntsa thiab tuaj yeem tswj tau ntawm ob sab.

Lub luag haujlwm ntawm low-voltage switchgear feem ntau yog raws li hauv qab no:

1. Tsim nyog teeb tsa lub hwj chim;

2. Thaum muaj qhov yuam kev hauv Circuit Court, nws muaj txiaj ntsig zoo rau kev tswj xyuas qhov kev ua txhaum thiab ua kom yooj yim rau kev txheeb xyuas sai thiab tshem tawm ntawm qhov txhaum;

3. Ib qho yooj yim los npaj cov kab tu hauv ntu yam tsis tas yuav muaj hluav taws xob loj loj;

4. Kev tso chaw yooj yim ntawm ntau yam khoom siv tiv thaiv hauv lub txee faib khoom (xws li fuses los tiv thaiv luv luv Circuit Court, cua hloov pauv kom tsis txhob muaj overload, thiab lwm yam)

Niaj hnub no txoj kev loj hlob sai ntawm cov khoom siv hluav taws xob ua tiav, kev ua haujlwm nyab xeeb thiab ruaj khov ntawm cov hluav taws xob qis hluav taws xob yog qhov tseem ceeb. Nrog rau qhov nyuaj thiab qhov tob ntawm kev lag luam hluav taws xob thiab daim ntawv thov, qhov ua tau ntawm cov hluav taws xob tsis tshua muaj hluav taws xob switchgear malfunctions kuj tau nce.

Tej teeb meem uas yuav tshwm sim nyob rau hauv low-voltage switchgear muaj xws li tsis muaj peev xwm ntawm Circuit Court breakers kaw, tsis muaj peev xwm ntawm lub ntsiab hloov nyob rau hauv lub txee nkag los qhib, lub reversal los yog tsis tig ntawm lub ntsiab metering reactive zog, tsis muaj peev xwm ntawm lub tub rau khoom. tig lub 'meter', thiab qhov tsis muaj peev xwm tuaj yeem hloov pauv ntawm ob lub zog hluav taws xob

GCK low-voltage switchgear yog cov cuab yeej siv hluav taws xob sib txuas nrog cov khoom zoo xws li cov qauv kev cog lus, ua tiav cov haujlwm, thiab kev ua haujlwm yooj yim. Nws yog dav siv nyob rau hauv ntau yam kev lag luam thiab pej xeem lub tsev fais fab faib tshuab.

Cov qauv yooj yim ntawm GCK low-voltage switchgear plhaub muaj xws li lub ntsiab busbar chav tsev, ceg Circuit Court breaker chav, hloov chav tswj, chav cable, teeb pom kev zoo, thiab lwm yam.

1. Lub tsev busbar tseem ceeb nyob rau sab saum toj ntawm GCK low-voltage switchgear thiab muaj ib lub thawv ntim. Muaj peb lub busbars ntsia rau hauv lub ntsiab busbar chav tsev, uas txuas nrog lub txee nkag los ntawm lub davhlau ya nyob twg blocks thiab yog lub luag hauj lwm rau inputing hwj chim rau tag nrho cov circuits nyob rau hauv lub GCK low-voltage switchgear.

2. Lub chav tsev Circuit Court breaker yog nyob rau hauv qab ntawm lub ntsiab busbar chav tsev thiab occupies ib tug loj cheeb tsam nyob rau hauv lub GCK low-voltage switchgear. Qhov no yog qhov tseem ceeb ntawm tag nrho cov switchgear, feem ntau yog siv rau kev txhim kho cov khoom xws li ceg Circuit Court breakers, tam sim no transformers, fuses, thiab lwm yam., kom ua tiav tam sim no branching, xyuas, thiab kev tiv thaiv. Kuj tseem muaj cov lus qhia fais fab, teeb pom kev ua txhaum, thiab lwm yam khoom siv tau nruab rau hauv chav tsev hluav taws xob hluav taws xob.

3. Chav tswj kev hloov pauv nyob hauv qab ntawm chav tsev hluav taws xob hluav taws xob thiab yog thaj chaw me me hauv GCK low-voltage switchgear. Chav tswj kev hloov pauv tau nruab nrog ntau yam kev tswj hwm thiab cov teeb pom kev zoo, xws li cov nyees khawm, qhov taw qhia teeb, cov chaw taws teeb tswj interfaces, fuses, thiab lwm yam, kom ua tiav kev hloov pauv thiab saib xyuas.

4. Lub chav cable yog nyob rau hauv qab ntawm GCK low-voltage switchgear, feem ntau yog siv rau kev txhim kho ntau yam kab nkag thiab tawm, thiab kev saib xyuas thiab kev tiv thaiv. Chav tsev cable kuj tseem muaj cov cuab yeej txhawb nqa xws li cua hloov pauv thiab fuses kom muaj kev nyab xeeb ntawm cov khoom siv hluav taws xob ntau.

5. Lub teeb pom kev zoo yog feem ntau ntsia saum toj los yog sab ntawm GCK low-voltage switchgear casing los muab cov teeb pom kev zoo rau cov neeg siv. Cov teeb pom kev zoo tuaj yeem txuas tau ntau yam teeb pom kev zoo xws li LED teeb thiab fluorescent tubes, ua rau cov neeg ua haujlwm kom pom tseeb ntawm sab hauv ntawm lub switchgear thiab txhim kho kev ua haujlwm.

Kev pabcuam ib puag ncig

a) Cua kub: Qhov kub siab tshaj plaws: ntxiv rau 40 degree; Qhov kub thiab txias: -15 degree

b) Cov av noo: Lub hli nruab nrab cov av noo 95 feem pua; Qhov nruab nrab av noo txhua hnub 90 feem pua.

c) Qhov siab tshaj qhov dej hiav txwv: Qhov siab tshaj plaws installation qhov siab: 1000M.

d) Cov huab cua nyob ib puag ncig tsis pom meej muaj kuab paug los ntawm corrosive thiab flammable gas, vapor thiab lwm yam.

e) Tsis tshua muaj kev kub ntxhov

Technical Parameter

Qib tiv thaiv

1P40

Rated ua hauj lwm voltage

AC, 380 (V)

Ntau zaus

50 Hz

Rated rwb thaiv tsev voltage

660V

Cov xwm txheej ua haujlwm

Ib puag ncig

Hauv tsev

Qhov siab

Tsawg dua los yog sib npaug li 2000m

Ambient kub

-5 degree ~ ntxiv rau 40 degree

Qhov ntsuas kub min nyob hauv khw thiab kev thauj mus los

-30 degree

kwv tij hmoob

Tsawg dua lossis sib npaug li 90 feem pua

Tswj lub cev muaj zog (kW)

0.4~155

PRODUCT PHOTO

20230427154920

20230427154934

20230427154946

20230427155040

20230427155054

GCK 13

GCK

CHAW UA HAUJ LWM

product-960-1274

PACKING & xa khoom

baozhuang

product-752-497

EXHIBITION

product-808-808

FAQ

Q5: Puas yog OEM / ODM muaj?

A: Yog, nws yog! Peb cov khoom tuaj yeem tsim kho. Peb muaj pab pawg tsim thiab engineers, peb tuaj yeem kho cov khoom raws li cov neeg siv khoom kos duab lossis cov kev xav tau.

Q6: Koj puas yog cov chaw tsim khoom lossis tuam txhab lag luam?
A: Peb yog lub Hoobkas, Raws li 100 feem pua ​​​​cov chaw tsim khoom nrog 20 xyoo kev tsim khoom, peb tuaj yeem tsim cov khoom raws li cov neeg siv khoom xav tau thiab peb tuaj yeem tswj cov khoom zoo 100 feem pua.

Q7: Tus nqi puas tuaj yeem sib tham?

A: Yog, tus nqi sib tham. Nws tuaj yeem hloov pauv raws li koj qhov ntau lossis pob

Q8: Ua li cas txog kev tshuaj xyuas?

A: Peb muaj tag nrho cov kev tshuaj xyuas los ntawm cov khoom siv raw mus rau qhov kawg cov khoom suav nrog kev ntsuas kub nce, ntsev tsuag tshuaj ntsuam xyuas tus neeg xyuas pib hom kev xeem, kev sim lub neej.

Q9: Cov nqe lus them nqi yog dab tsi?

A: TT, Paypal, Western Union, Alibaba kev lees paub kev lag luam thiab L / C tau txais. 30 feem pua ​​​​T / T ua ntej, 70 feem pua ​​​​ua ntej xa zaub mov.

Q10: Lub tuam txhab muab kev pabcuam yog dab tsi?

A: Peb muaj cov kws tshaj lij engineer pab pawg uas tuaj yeem tsim thiab tsim pwm kom tuaj txog cov neeg siv khoom sib txawv.

Peb kuj muaj pab pawg muag khoom los muab kev pabcuam zoo los ntawm kev muag khoom ua ntej mus rau tom qab muag.

Cov khoom no feem ntau yog customized.
Peb yog cov chaw tsim khoom thiab muaj lub tuam txhab kev tshaj lij uas tuaj yeem tsim thiab muab kev daws teeb meem raws li cov neeg siv khoom xav tau.
Thov hu rau peb cov neeg muag khoom kom tau txais cov duab kos duab

 

Nov yog peb cov neeg siv khoom piv txwv rau koj siv

Nepalese cov neeg siv khoom

GCS LV rho tawm Switchgear
S.N. Specifications Yog / Tsis yog / Yog tias muaj
Hluav taws xob vaj huam sib luag (Low-voltage rho tawm switchgear txee)
Chaw tsim tshuaj paus
Hom
Hom / Qauv GCS
Lub Tebchaws Keeb Kwm
1 Kev piav qhia ntawm Function
1.1 Nws yog pab pawg ntawm cov tsis tshua muaj hluav taws xob hloov hluav taws xob tshem tawm txee uas tuaj yeem ua haujlwm tau yooj yim thiab nyab xeeb.
2 Cov kev xav tau ua haujlwm
2.1 Cov khoom siv hluav taws xob tuaj yeem raug txiav tawm manually thiab txiav tawm thaum lub sijhawm overload thiab luv-circuit.
3 System configuration
3.1 Tsawg voltage switchgear tshem tau txee nrog tag nrho cov khoom tseem ceeb thiab tooj liab busbar
4 Technical Specifications Kev ntsuas
4.1 Main Circuit Court ntsuas voltage 400V
4.2 Rated zaus 50 Hz
4.3 Rated insultation voltage 690V (1000V)
4.4 Maximum ua hauj lwm tam sim no ntawm lub ntsiab busbar (tooj liab) 1000A
4.5 Rated withstand tam sim no ntawm lub ntsiab busbar 100 KA/1s
4.6 Qib tiv thaiv IP40
4.7 Kev ua haujlwm hom Phau ntawv thiab Automatic
4.8 Hlau tub rau khoom hom 8E lossis 16E lossis sib npaug
4.8.1 400A tub rau khoom 1 Tsis muaj.
4.8.2 300A tub rau khoom 1 Tsis muaj.
4.8.3 250A tub rau khoom 1 Tsis muaj.
4.8.4 200A tub rau khoom 2 Tsis muaj.
4.8.5 150A tub rau khoom 2 Tsis muaj.
4.8.6 100A tub rau khoom 2 Tsis muaj.
4.9 Sab nrauv Dimension Kwv yees li. 80 x 105 x 220 cm
4.10 Txhua tus tub rau khoom yuav tsum muaj 3-digital lossis analog ammeter los ntsuas 3-theem (RYB) tam sim no ib tus zuj zus
4.11 Busbar yuav tsum yog tooj liab peb theem plaub hlau nrog tiv thaiv Earthing (R, Y, B, N, PE).
4.12 MCCB yuav tsum yog qhov zoo & rhiab heev
4.13 Kev khiav hauj lwm mechanism ntawm drawers yuav tsum yooj yim thiab du.
4.14 Drawer Handle yuav tsum tau insulated heev thiab muaj zog
4.15 Sab nrauv qhov ntev yuav tsum kwv yees sib phim rau (80cm X 105cm X 220cm)
4.16 Sab nrauv tsim thiab xim yuav tsum sib phim raws li tus qauv tsim raws li pom hauv daim duab
5 Busbar Tais
5.1 Lub tais busbar yuav tsum tau muab ntsia rau saum toj ntawm lub compartment ntawm chav tsev ua haujlwm, thiab cov kab txuas thiab cov khoom siv hluav taws xob ntau tuaj yeem muab tso rau hauv lub tais.
5.2 Tus naj npawb ntawm Busbar yuav tsum tau txuas nrog los ntawm cov kab ke uas twb muaj lawm rau kev teeb tsa txee los ntawm cov txiv ntoo-bolt / Busbar trunking system raws li qhov xav tau
6 Accessories, spares thiab consumables

 