Tag nrho cov qauv ntawm cov khoom yog cov qauv kev sib xyaw ua ke noj hloov lub cev raws li kev ua haujlwm mechanism, txais yuav cov qauv kev sib xyaw ua ke, tsis muaj kuab paug, tsis muaj kev tawg, tsis muaj kev phom sij rau kev tiv thaiv siab.
Hauj lwm lawm
Lub Tsau Kho Cov Hluav Taws Xob Hluav Taws Xob Cov Hluav Taws Xob Cov Hluav Taws Xob yog qhov tsim nyog rau 12kV voltage, dav siv nyob rau hauv cov chaw ua hluav taws xob, chaw hloov pauv, thiab lwm yam khoom siv hluav taws xob, raws li kev tiv thaiv thiab tswj cov chaw hluav taws xob, tshwj xeeb tshaj yog rau qhov chaw uas cov khoom lag luam nquag ua haujlwm raws li qhov ntsuas tam sim no thiab ntau tawg tam sim no. Tag nrho cov qauv ntawm cov khoom yog cov qauv kev sib xyaw ua ke noj hloov lub cev raws li kev ua haujlwm mechanism, txais yuav cov qauv kev sib xyaw ua ke, tsis muaj kuab paug, tsis muaj kev tawg, tsis muaj kev phom sij rau kev tiv thaiv siab.
Tsis:
1.Txhob Voltage: 12kV
2.Cov nqi hluav taws xob tiv taus voltage (1 feeb): 75kV
3. lub teeb impulse tiv taus voltage: 42kV
4. luv luv-Circuit Court tawg tam sim no: 20 / 31.5 / 40kA
5.Txiav Tam Sim No: 630 / 1250A
6.Rated thermal stability tam sim no (siv tau tus nqi zoo): 20 / 25kA
7.Txhais muaj kev ruaj khov tam sim no (tus nqi siab): 50 / 63kA
8. luv luv-Circuit Court ua tam sim no (ncov tus nqi): 50 / 63kA
9. luv luv Circuit Court tawg lub sij hawm tawg tam sim no: 50 zaug
10.Power zaus tiv taus voltage ntawm theem nrab Circuit Court (1min): 2000V
11.Rated ua haujlwm ntu: O-0.3s-C0-180s-CO
12.Red ib / rov qab mus rau rov qab capacitor bank tsoo nyiaj tam sim no: 630/400 800 / 400kA
13.Mechanical lub neej: 0050000≥50000≥30000 lub sijhawm
Kev siv ntawm ib puag ncig puag:
1. Kev ntsuas kub ntawm huab cua: tsis siab tshaj +40 ° C, tsis pub tsawg dua -15 ° C (ntawm -30 ° C kom tso cai cia thiab thauj).
2. Qhov siab: tsis pub tshaj 1000m.
3. Tus ntsuas cua sib txawv: txhua hnub nruab nrab ntawm tsis tshaj 90%, lub hli nruab nrab tsis tshaj 90%. saturated vapor siab qhov nruab nrab txhua hnub tsis tshaj li 2.2 × 10-3MPa, ib hlis ib hlis tsis tshaj 1.8 × 10-3MPa.
4. Av qeeg siv: tsis tshaj li yim.
5. Tsis muaj hluav taws kub, tawg muaj kev phom sij, muaj qhov qias neeg, tshuaj lom neeg xeb, nrog rau cov chaw ntawm kev co.



Peb Cov Kev Pab:
1.Koj qhov kev nug muaj feem xyuam nrog peb cov khoom& tus nqi yuav teb tuaj rau hauv 24 teev.
2.Well-kawm& cov neeg ua haujlwm paub tau zoo yog los teb tag nrho koj cov lus nug.
3. Mekas kev daws teeb meem& kev pabcuam zoo meej tomqab muag.
4. Peb qhov zoo dua: A.Competitive nqe B.Reliable Zoo C.On-lub sijhawm khoom xa tuaj D.Professional tsim pab pawg

Peb cov khoom:

Cim npe nrov: tsau siab qhov hluav taws xob hluav taws xob Circuit Court breaker, Tuam Tshoj, tuam ntxhab, cov chaw muag khoom, kho kom haum