Sab Hauv Tsev SF6 Lub Kauj Tsev Tseem Ceeb

Sab Hauv Tsev SF6 Lub Kauj Tsev Tseem Ceeb

Sab Hauv Tsev SF6 Lub nplhaib Loj Chav RMR yog lub nplhaib lub ntsej muag tseem ceeb rau kev tshaj tawm cov khoom sib txuas. RMR tuaj yeem muab 10 qhov kev teeb tsa sib txawv, haum rau feem ntau hloov daim ntawv thov hauv 12/24 kV kev faib khoom siv. Nws yog qhov ua tau thiab ua ke nrog ABB' s hloov tau yooj yim thiab cov pob hluav taws xob hloov ...

Hauj lwm lawm

Sab Hauv Tsev SF6 Lub Kauj Tsev Tseem Ceeb

RMR yog cov nplhaib lub ntsej muag tseem ceeb rau kev faib hluav taws xob asecondary network. RMR tuaj yeem muab 10 qhov kev teeb tsa sib txawv, haum rau feem ntau hloov daim ntawv thov hauv 12/24 kV kev faib khoom siv. Nws yog qhov ua tau thiab ua ke nrog ABB' s hloov pauv yooj yim thiab compact switchgear SafePlus lub tswv yim, nws yog ua tiav kev daws teeb meem rau 12/24 kV thib ob faib tes hauj lwm. RMR thiab SafePlus muaj tib lub interface. RMR yog kev kaw ruaj khov ua ke nrog lub taub ntim tsis muaj cov hlaus tsis zoo uas muaj txhua qhov chaw nyob thiab hloov mus ua haujlwm. Kaw cov hlau tso tsheb hlau luam nrog cov huab cua tsis tu ncua kom ntseeg tau tias muaj kev ntseeg siab raws li kev ruaj ntseg ntawm cov neeg ua haujlwm thiab yuav luag tu cov neeg ua haujlwm. Lub tswvyim RMR muab kev xaiv ntawm kev hloov fuse txuas lossis cov hluav taws xob sib txuas nrog cov kev xa tawm mus tiv thaiv lub hloov hluav taws xob. RMR tuaj yeem muab kev sib xyaw cov chaw taws teeb tswj hwm thiab ntsuas xyuas. Cov khoom no ua raws li cov qauv ntawm IEC60420, GB / T11022, GB3804, GB3906


SF6 sab hauv tsev lub ntsiab chav tsev siv ib puag ncig:

a) Cov cua kub: qhov kub tshaj plaws: +40 ​​℃; qis tshaj kub: -20 ℃

b) Vaum: txhua hli nruab nrab av noo 95%; txhua hnub nruab nrab av noo 90%.

c) Qhov siab: qhov siab tshaj plaws teeb tsa: 2500m

d) Pom tsis muaj huab cua ua pa paug los ntawm cov roj paug thiab cov pa taws, khov, thiab lwm yam


Cov ntaub ntawv txheej txheem

Tsis yog.

Yam khoom

Chav Nyob

C Module

V Module

Thauj khoom tawg mus

Circuit Court tej fais fab

1

Rated voltage

kV

12

24

12

24

2

Nyob tam sim no

A

630

3

Nyob ua ntau zaus

Hz

50/60

4

1min Fais fab zaus tiv taus qhov hluav taws xob

kV

45

55

45

55

5

Xob laim impulse tiv taus voltage

kV

75

125/150

75

125/150

6

Nyob hloov tam sim no

A

1700

1400


7

Rated nquag load thiab kaw Circuit Court txhaum tam sim no

A

630

8

Nyob cable them txhaum tam sim no

A

50& 10

9

Nyob luv luv Circuit Court tawg tam sim no

kA


20

16

10

Nyob luv Circuit Court ua tam sim no (ncov)

kA

63

50

63

50

11

Lub sijhawm luv (2s) tiv taus tam sim no, load hloov / lub ntiaj teb

kA

25/20

20/20

25/20

20/20

12

Nyob mas tam sim no (ncov)

kA

63

50

63

50

13

Mechanism lub neej

Lub Sijhawm

3000

10000

3000

14

Qhov ntev (rau ib koog)

hli

370x750x1345


SF6 Insulated Ring Main Unit

SF6 RMU Switchgear


FAQ:

1. Koj puas yog cov tsim khoom lossis chaw lag luam?

Fengyuan Fais Fab yog lub chaw tsim khoom lag luam tshaj lij nyob hauv Henan, Suav

2. Koj lub lag luam tseem ceeb yog dab tsi?

Peb lub khw muag khoom tseem ceeb nyob hauv cov teb chaws Es Xias Qab Teb, Middle East, West Africa, Eastern Europe lub teb chaws thiab qee lub lag luam South American domestic thiab ib nrab lag luam.

3.Yog li cas txog koj txoj kev xa khoom thiab kev pab cuam tom qab muag?

Kev xa tawm raws li kev txiav txim kom muaj nuj nqis, feem ntau peb xav tau 1 lub hlis rau kev txiav txim cov thawv. 20 lub taub ntim (20 ko taw lossis 40 ko taw) hauv ib hlis yog tsis muaj teeb meem rau peb. Peb tuaj yeem teb cov neeg siv cov lus nug thiab daws lawv cov teeb meem 24 teev nyob rau ib hnub, thiab muab kev txhawb nqa kev qhia tau zoo rau txhua yam peb cov khoom raws sijhawm.

4. Dab tsi yog koj cov khoom lag luam lav?

Ua ntej tshaj plaws, peb cov hloov pauv thiab cov khoom siv fais fab muaj CCC, ISO9001 ... thiab lwm yam. cov ntawv pov thawj zoo, thiab nws cov khoom siv hluav taws xob thiab khoom siv tau CE, Rohs, CB, TUV, Kema ... Qhov ob, peb muab 1 xyoo lav zoo.

5. Koj puas kam txais OEM thiab ODM?

Yog lawm. Peb R& D pab pawg muaj cov thev naus laus zis tshiab kawg thiab tuaj yeem tsim kho thiab tsim khoom raws li cov neeg siv' kos duab thiab hom

Cim npe nrov: sab hauv tsev sf6 nplhaib lub ntsiab, Suav teb, chaw tsim khoom, chaw muag khoom, Mekas

(0/10)

clearall