KYN61-40.5 21.6KV Hloov Board Hluav Taws Xob
Lub ntsiab feature ntawm KYN61-40.5 hom armored tshem tau AC hlau enclosed switchgear (tom qab no hu ua "switchgear") yog tias lub txee yog nruab nrog ZN85-40.5 thiab VD4, VB2 tag nrho insulated nqus tsev vacuum Circuit Court breaker thiab caij nplooj ntoos hlav kev khiav hauj lwm mechanism. Lub txee lub cev yog ua los ntawm txhuas-zinc phaj, uas txhim kho qhov haum qhov tseeb ntawm lub tawb nqa khoom thiab lub txee lub cev. Nws yog qhov yooj yim heev rau swb rau hauv thiab tawm ntawm lub tawb nqa khoom, uas tuaj yeem hloov pauv tau. Cov tsos zoo nkauj thiab cov tswv yim ua tiav, uas muaj kev nyab xeeb thiab txhim khu kev qha.Cov khoom no yog siv rau hauv 35kV peb-theem AC 50Hz fais fab system, rau kev hloov chav tsev fais fab nroj tsuag, substations thiab industrial thiab mining lag luam txais thiab faib fais fab, nrog tswj, tiv thaiv thiab saib xyuas lub luag haujlwm.Cov khoom no ua raws li: GB3906"3-35kV AC hlau enclosed switchgear", GB/T11022"cov kev xav tau ntawm high-voltage switchgear thiab tswj cov khoom txheem", DL/T404 "kev txiav txim technical Cov xwm txheej ntawm AC high-voltage hloov txee", IEC298 "AC hlau-pob qhov hloov pauv thiab cov cuab yeej tswj hwm nrog cov ntsuas hluav taws xob 1kV saum 52kV thiab qis dua" cov qauv.
Hauj lwm lawm
KYN61-40 5 21.6KV hluav taws xob hloov hluav taws xob
KYN61-40.5 series Hlau-clad thim tau AC hlau-kab hloov pauv txee yog ib yam khoom tshiab tsis ntev los no tsim thiab tsim los ntawm Xi'an High Voltage Hluav Taws Xob Tshawb Fawb Lub Tsev Haujlwm. Lub switchgear thav duab yog hlau-clad hom qauv tsim, nyob rau hauv nruab nrog tshiab tag nrho-insulating lub tshuab nqus tsev Circuit Court breaker los yog sulfur hexafluoride Circuit Court breaker. Lub switchgear lub cev siv cov qauv ntim, uas txhim kho cov tsos zoo thiab raug raug, thiab ua kom lub voj voog ntau lawm. Kev ua haujlwm ib txwm ua ntawm switchgear coj nyob rau hauv cov xwm txheej ntawm kev kub siab cais chav nrog lub qhov rooj kaw. Lub switchgear txee ua raws li kev cai ntawm IEC-60298, GB3906, nrog lub suab "tsib tiv thaiv" muaj nuj nqi.
1.Kev tiv thaiv qib siab
2.Kev hloov pauv hloov yooj yim
3.Zoo handcart interchangeability
4. Tsawg dua cheeb tsam
5. Kev ruaj ntseg siab
6.Reliable interlock ntaus ntawv kom tsis txhob misoperation
KYN61-40.5 huab cua-insulated hlau-clad tshem tau switchgear (tom qab no ua "switchgear") yog ib qho tsim nyog cov khoom siv hluav taws xob hauv tsev hauv 40.5 kV 3-theem AC 50Hz. Nws yog tsuas yog siv los faib hluav taws xob hluav taws xob hauv qhov chaw nres tsheb fais fab thiab cov chaw nres tsheb ntawm kuv, kev lag luam thiab cov khoom siv hluav taws xob. Tsis tas li ntawd nws yog siv rau hauv kev tswj, kev tiv thaiv thiab kev saib xyuas thiab lwm yam rau kab Circuit Court raws li nquag ua hauj lwm site.
1. Ambient kub:-10oC ~ ntxiv rau 40oC, thiab ntsuas qhov nruab nrab RH hauv 24 teev Tsawg dua lossis sib npaug li 35oC;
2. Qhov siab: Tsis tshaj 1000m saum hiav txwv;
3. Ambient humidity: Qhov nruab nrab txhua hnub RH Tsawg dua lossis sib npaug li 95 feem pua; Lub hli nruab nrab RH Tsawg dua lossis sib npaug li 90 feem pua
4. Kev siv av qeeg: Tsawg dua lossis sib npaug rau Qib 8
5. Dej vapor siab: nruab nrab txhua hnub RH Tsawg dua lossis sib npaug li 2.2kPa; Lub hli nruab nrab RH Tsawg dua lossis sib npaug rau 1.8kPa;
6. Ambient ib puag ncig: tsis muaj hluav taws kub, tawg txaus ntshai, muaj kuab paug loj, tshuaj corrosion thiab qhov chaw vibration loj
Technical Parameter
Tsis muaj. | Cov khoom | Chav tsev | Tsis muaj | ||
1 | Rated voltage | KV | 40.5 | ||
2 | Rated zaus | Hz | 50 | ||
3 | Lub ntsiab busbar ntsuas tam sim no | A | 1250,1600,1200 | ||
4 | Ceg busbar ntsuas tam sim no | A | 630/1250/ 1600 | ||
5 | Rated rwb thaiv tsev theem | Fais fab zaus withstand voltage nyob rau hauv 1min (zoo tus nqi) | Phase-phase, Phase-hauv av | KV | 95 |
| KV | 115 | |||
Lightning Impulse Withstand Voltage (tus nqi siab tshaj) | Phase-phase, Phase-hauv av | KV | 185 | ||
| KV | 215 | |||
Fais fab zaus withstand voltage ntawm pab tswj Circuit Court | V | 2000 | |||
6 | Rated luv Circuit Court breaking tam sim no | KA | 25/31.5 | ||
7 | Rated luv Circuit Court kaw tam sim no (peak tus nqi) | KA | 63/80 | ||
8 | Rated luv-lub sij hawm tiv taus tam sim no (4S) | KA | 25/31.5 | ||
9 | Rated ncov tiv taus tam sim no | KA | 63/80 | ||
10 | Rated voltage ntawm pab tswj Circuit Court | V | -110,-220,~220 | ||
11 | Qib tiv thaiv | Enclosure IP4X, IP2X Thaum lub qhov rooj ntawm Circuit Court breaker qhib | |||
12 | Qhov loj me (dav * qhov tob * qhov siab) | mm | 1400 (1200) * 2800 (2600) * 2600 (* suav nrog cov txheej txheem SF6 sab hauv) | ||
13 | hnyav | kg | ~2300 | ||






Factory

CERTIFICATE




EXHIBITION

LUB TSEV KAWM NTAWV

PACKING & xa khoom


FAQ
Q5 : Puas yog OEM / ODM muaj?
A: Yog, nws yog! Peb cov khoom tuaj yeem tsim kho. Peb muaj pab pawg tsim thiab engineers, peb tuaj yeem kho cov khoom raws li cov neeg siv khoom kos duab lossis cov kev xav tau.
Q6 : Koj yog cov chaw tsim khoom lossis tuam txhab lag luam?
A: Peb yog lub Hoobkas, Raws li 100 feem pua ntawm cov chaw tsim khoom nrog 20 xyoo kev tsim khoom, peb tuaj yeem tsim cov khoom raws li cov neeg siv khoom xav tau thiab peb tuaj yeem tswj cov khoom zoo 100 feem pua.
Q7 : Tus nqi puas tuaj yeem sib tham?
A: Yog, tus nqi sib tham. Nws tuaj yeem hloov pauv raws li koj qhov ntau lossis pob
Q8 : Yuav ua li cas txog kev tshuaj xyuas?
A: Peb muaj tag nrho cov kev tshuaj xyuas los ntawm cov khoom siv raw mus rau qhov kawg cov khoom suav nrog kev ntsuas kub nce, ntsev tsuag tshuaj ntsuam xyuas tus neeg xyuas pib hom kev xeem, kev sim lub neej.
Q9 : Cov nqe lus them nqi yog dab tsi?
A: TT, Paypal, Western Union, Alibaba kev lees paub kev lag luam thiab L / C tau txais. 30 feem pua T / T ua ntej, 70 feem pua ua ntej xa zaub mov.
NYEEM VIDEO
https://www.facebook.com/bob.niu.35/
Youtube
www.youtube.com/channel/UC5IP4dL0UTQG4fgAOa3UhWA
https://twitter.com/FengyuanE
Txais tos kom nug
Cov ntaub ntawv tiv tauj:
Jiyuan Fengyuan Electrical Equipment Co., Ltd
Kev Muag Khoom
Hu rau tus neeg: Mr Charles Du
E-mail:fengyuan800@outlook.com
Txawb: ntxiv rau 8618639199897(Muaj rau whatsapp, wechat, skype)
Ntxiv: Huling industrial tsam, jiyuancity, henan xeev, Suav teb
TEL: ntxiv rau 86-0391-2180800
Fax: plus 86-0391-2180818
Cim npe nrov: kyn61-40.5 21.6kv hloov board hluav taws xob, Tuam Tshoj, tuam ntxhab, lwm tus muag khoom, customized